ABB Rapid Shutdown Combiner Box with Disconnect Switch - RS2-2PN6-KIT |
ABB, Rapid Shutdown Combiner Box with Disconnect Switch, 2x2 Max Strings In - 2 Combined String Out, 11.25 A per String, 600 Volts, NEMA 4X, RS2-2PN6-KIT ABB now offers the only family of rapid shutdown products for string inverters today.This product provides a fail-safe solution for emergency responders to eliminate voltage at the PV array in compliance with NEC 2014 Rapid Shutdown code requirements. The ABB Rapid Shutdown system requires no extra conduit; minimizing additional material cost and associated labor. Shutdown occurs at the rooftop box Three models are available to cover all system configurations; including, a two-string pass through, a two-string combined and a four-string combined box. The unique features of each box can be used to maintain the specific configuration of the PV system. Dual outputs in the box maintain the benefits of ABB’s dual MPPT inverter channels, while the single output box is perfect for small PV arrays utilizing one MPPT channel or systems requiring two rapid shutdown boxes. To further reduce system cost, string combining models reduce the number of output conductors between the rooftop box and the inverter. The applicable rapid shutdown boxes include disconnect switches to comply with NEC 2014 690.15(C) Direct-Current Combiner Disconnects . |
Features
|
General Information | |
Manufacturer: | ABB |
Product Line: |
RS Series |
Model ID: |
RS2-2PN6-KIT |
Certifications and Safety Ratings: | |
Mechanical Data |
|
Dimensions: |
10.54 x 8.54 x 5.32 inches (without Mounting Bracket) |
Weight: | 5.80 lbs |
Mount Angle: | 0-90° |
Operating Temperature Range: | -25°C to +70°C |
Enclosure Rating: | NEMA 4X |
Certifications: | UL1741:2010, FCC Part 15 Class B |
Rapid Shutdown Kit: | RS2-1CN6-KIT |
Rapid Shutdown Rooftop Box for 2-Box System: | RS2-1CN6 |
Optional Emergency Stop: | 1SFA611821R1026 |
Electrical Data |
|
PV Source Conductor Input | |
Maximum Input Current: | 11.25 Amps Per String |
Maximum Input Voltage: | 600 Volts |
Number of Input Strings: | 2 |
Conductor Size: | 14-8 AWG |
PV Output Conductors Output |
|
Number of Output Currents: |
1 |
Conductor Size: | 12-6 AWG |
DC Disconnect: | Yes |
Control Power |
|
Power Consumption: | <2.5W, 24V/0.1A |
Maximum Power Conductor Size: | 12 AWG |
E-Stop Button: | Optional |
Datasheets |
|
Document | Type |
ABB RS2-2PN6-KIT Specifications | Specifications |
Warranty | 10 Year Standard Warranty |
ABB RS2-2PN6-KIT Warranty | Warranty |
Terms & Conditions |
|
Shipping: | Shipping Policy |
Returns: | Returns Policy |
Payments: | We accept: Visa, MasterCard, Discover, and American Express. We also accept checks, direct deposit and wire transfers for large orders. |
Warranty: 10 Year Standard Warranty