Samlex America, 300w Battery Inverter, Pure Sine Wave Series, 24VDC, 120VAC, 60Hz, PST-300-24 This high efficiency DC-AC inverter converts 24 Volts DC to 300 Watts of pure sine-wave AC power at 120 Volts, 60 Hz. The unit comes with detachable cable with 12V plug adaptor and cable with battery clamps. Features include overload protection, low battery alarm / shut down, low idle power draw of less than 0.5 Amps. AC power is available from a NEMA-20R GFCI duplex outlet on the front panel. Safety certified to UL standards. |
Features
|
General Information | |
Manufacturer: | Samlex America |
Product Line: |
Pure Sine Wave |
Model ID: |
PST-300-24 |
Certifications and Safety Ratings: | ![]() ![]() ![]() ![]() |
Mechanical Data |
|
Technology: | Battery Inverter |
Dimensions: |
6.10 x 9.69 x 2.58 inches |
Weight: | 3.46 lbs |
AC Output Connections: | NEMA 5-15R GFCI Duplex Outlets |
Display: | LED: Power, Abnormal |
Cooling: | Temperature Controlled Fan - On at Internal Hot Spot > 48°C. Off at 42°C |
DC Input Connections: | 5 x 40A = 200A (Each 40A, 32V, Automotive, Blade Type) |
Safety: | Intertek - ETL Listed. Conforms to ANSI/UL Standard 458 and Certified to CSA Standard C22.2 No. 107.1-01 |
EMI/EMC: | FCC Part 15(B), Class B |
Operating Temperature Range: | -20°C to +40°C |
Electrical Data |
|
Output Voltage: |
120 VAC ± 3% |
Maximum Output Current: | 12.54 Amps |
Output Frequency: | 60 Hz ± 1% |
Output Voltage Waveform: | Pure Sine Wave |
Total Harmonic Distortion: | <3% |
Continuous Output Power: | 300 Watts |
Surge Output Power: | 500 Watts (< 8 ms) |
Peak Efficiency: | > 89% |
Nominal DC Input Voltage: | 24Volts |
DC Input Voltage Range: | 21.0 - 33.0 VDC |
Maximum Input Current: | 20 Amps |
DC Input Current at No Load: | < 400 mA |
DC Input Connections: | Hole Diameter: 5 mm; Set Screw: #10, 24TPI |
Low DC Input Voltage Alarm: | 21 Volts |
Low DC Input Voltage Shutdown: | 20 Volts; Auto Reset at 23 Volts |
High DC Input Voltage Shutdown: | 33 Volts; Auto Reset at < 33 Volts |
Short Circuit Shutdown: | When Output Voltage Drops to 80 Volts or Lower for 5 Sec |
Overload Shutdown: | At Overload of 110% to 115% for 2 to 2.5 Sec |
Ground Fault Shutdown: | Through NEMA 5-20R GFCI Duplex Outlets |
Over Temperature Shutdown: | At Internal Hot Spot Temp of 95°C. Auto Reset at 70°C |
Reverse Polarity on DC Input Side: | Internal DC Sides Fuses Will Blow |
Datasheets |
|
Document | Type |
![]() |
Specifications |
![]() |
Installation Guide |
Warranty | 2 Year Limited Warranty |
Terms & Conditions |
|
Shipping: | Shipping Policy |
Returns: | Returns Policy |
Payments: | We accept: Visa, MasterCard, Discover, and American Express. We also accept checks, direct deposit and wire transfers for large orders. |
Warranty: 2 Year Limited Warranty